Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter

    Buy cheap Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter from wholesalers
     
    Buy cheap Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter from wholesalers
    • Buy cheap Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter from wholesalers
    • Buy cheap Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter from wholesalers

    Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter

    Ask Lasest Price
    Brand Name :
    Model Number : ML-6100S
    Price : Negotation
    Payment Terms : T/T
    Supply Ability : 10000 units per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter

    Back Lit LCD Display RS232 RS485 Fixed Ultrasonic Flow Meter

    I. Introduction

    ML-6100S is a wall-mount, clamp- on type ultrasonic flow meter which uses the transit-time technology. Designed using FPGA chip and low-voltage broadband pulse transmission.Both clamp on type sensors and insertion type sensors are available.

    ML-6100S has a 240*128 back lit LCD with 4 line menu display and also the clear,user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly yearly totalizer. Parallel operation of positive, negative and net flow totalizer with scale factor (span) and BTUcapacity. While the output of totalizer pulse and frequency output are transmitted via relay and open collector.


    • External clamping flow meter sensor, simple and convenient installation, high flexibility
    • Integrated design and manufacturing, the true meaning of IP68 waterproof
    • Hidden pipe design, more beautiful after installation

    ML-6100S can be used in conjunction with the RTD module and the PT1000 temperature sensor to become an energy meter for measuring the heat and cold consumption of heating pipelines and air-conditioning refrigeration pipelines;

    The PT1000 uses high-temperature resistance lines, imported movements,and its sensitivity and working conditions durability are much higher than those of domestic PT100.


    II. Working Principle

    The clamp-on or tube-segment ultrasonic flow meter is a meter that measures the flow of liquid in a round tube based on the principle of the "speed difference method". It uses advanced multi-pulse technology, signal digital processing technology and error correction technology to make the flow meter more adaptable to the environment of the industrial site, and the measurement is more convenient, economical and accurate. The products have reached the advanced level at home and abroad, and can be widely used in petroleum, chemical, metallurgy, electric power, water supply and drainage fields.


    III. Specification

    Performance
    Velocity Range±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
    Accuracy±1% of measured value
    Repeatability0.2% of measured value
    Linearity±1%
    Pipe SizeDN25~DN1200(A pair of sensors)
    Function
    OutputAnalog output: 4~20mA, max load 750Ω.
    Pulse output: 0~10KHz
    CommunicationRS232/RS485 Modbus
    Power Supply10~36VDC/AC90~245V
    Display240*128 back lit LCD
    TemperatureTransmitter: -14℉~140℉(-20℃~60℃)
    Transducer:-40℉~176℉(-40℃~80℃,TT01)
    Transducer:-40℉~266℉(-40℃~130℃,TT03)
    HumidityUp to 99% RH,non-condensing
    Physical
    TransmitterPC/ABS,IP65
    TransducerEncapsulated design,IP68
    Double-shielded transducer cable
    Standard/maximum cable length:30ft/1000ft(9m/300m)

    IV. Straight Pipe Demand


    We suggest avoiding the valve, T-branch pipe and elbows if the condition allow.

    Please satisfied the hardest position installation requirements when you face more than one interfering resource.


    V. Configuration


    ModelTransmitter
    ML-6100SWall-mounted Type
    Velocity Range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
    Accuracy :±1% of the measure value
    Repeatability:0.2% of the measure value
    Display:240*128 back lit LCD
    Power Supply: 10~36VDC/AC90~245V
    Transmitter Enclosure: IP65, ABS (Temperature: -20℃~50℃)
    Output: OCT pulse output 0-10KHz, Relay output, 4-20mA for option
    Communication: RS232,RS485
    CodeOutput
    1OCT,Relay,RS232/RS485,4-20mA
    2OCT,Relay,RS232/RS485,4-20mA, RTD
    CodeTransducer
    TT01Clamp-on, IP68. Operating temperature:-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃)
    TT03Clamp-on, IP68. Operating temperature:-40 ℉ ~ +266℉(-40℃ ~ +130 ℃)
    TT05Insertion, IP68. Operating temperature:-40 ℉ ~ +266 ℉(-40℃ ~ +130 ℃)
    CodeTransducer Cable Length
    030Standard length 30ft (9m)
    XXXMax length to 1000ft (300m)
    CodeTemperature Transducer
    PT1000PT1000 temperature transducer+RTD module(option)
    CodeData Logger
    SDSD card(8G)+ SD card module(option)