    RS485 Ultrasonic Flow Meter

    RS485 Ultrasonic Flow Meter Sensor With High Temperature Up To 130C

    I. Introduction

    ML-6100S is a wall-mount, clamp- on type ultrasonic flow meter which uses the transit-time technology. Designed using FPGA chip and low-voltage broadband pulse transmission.Both clamp on type sensors and insertion type sensors are available.

    ML-6100S has a 240*128 back lit LCD with 4 line menu display and also the clear,user-friendly menu selections make flow meter more simple and convenient to use.Daily, monthly yearly totalizer. Parallel operation of positive, negative and net flow totalizer with scale factor (span) and BTUcapacity. While the output of totalizer pulse and frequency output are transmitted via relay and open collector.


    • External clamping flow meter sensor, simple and convenient installation, high flexibility
    • Integrated design and manufacturing, the true meaning of IP68 waterproof
    • Hidden pipe design, more beautiful after installation

    ML-6100S can be used in conjunction with the RTD module and the PT1000 temperature sensor to become an energy meter for measuring the heat and cold consumption of heating pipelines and air-conditioning refrigeration pipelines;

    The PT1000 uses high-temperature resistance lines, imported movements,and its sensitivity and working conditions durability are much higher than those of domestic PT100.


    II. Working Principle

    The external clamping or pipe type ultrasonic flow meter is an instrument to measure the liquid flow in the circular tube on the principle of speed difference method. It adopts advanced multi-pulse technology, signal digital processing technology and error correction technology, so that the flow meter can adapt to the environment of industrial site more conveniently, economically and accurately. Products reach the advanced level at home and abroad, can be widely used in petroleum, chemical, metallurgy, electricity, water supply and drainage and other fields.


    III. Specification

    Performance
    Velocity Range±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
    Accuracy±1% of measured value
    Repeatability0.2% of measured value
    Linearity±1%
    Pipe SizeDN25~DN1200(A pair of sensors)
    Function
    OutputAnalog output: 4~20mA, max load 750Ω.
    Pulse output: 0~10KHz
    CommunicationRS232/RS485 Modbus
    Power Supply10~36VDC/AC90~245V
    Display240*128 back lit LCD
    TemperatureTransmitter: -14℉~140℉(-20℃~60℃)
    Transducer:-40℉~176℉(-40℃~80℃,TT01)
    Transducer:-40℉~266℉(-40℃~130℃,TT03)
    HumidityUp to 99% RH,non-condensing
    Physical
    TransmitterPC/ABS,IP65
    TransducerEncapsulated design,IP68
    Double-shielded transducer cable
    Standard/maximum cable length:30ft/1000ft(9m/300m)

    IV. Configuration

    ModelTransmitter
    ML-6100SWall-mounted Type
    Velocity Range:±0.09ft/s ~ ±39ft/s (±0.03m/s ~ ±12m/s)
    Accuracy :±1% of the measure value
    Repeatability:0.2% of the measure value
    Display:240*128 back lit LCD
    Power Supply: 10~36VDC/AC90~245V
    Transmitter Enclosure: IP65, ABS (Temperature: -20℃~50℃)
    Output: OCT pulse output 0-10KHz, Relay output, 4-20mA for option
    Communication: RS232,RS485
    CodeOutput
    1OCT,Relay,RS232/RS485,4-20mA
    2OCT,Relay,RS232/RS485,4-20mA, RTD
    CodeTransducer
    TT01Clamp-on, IP68. Operating temperature:-40 ℉ ~ +176 ℉(-40℃ ~ +80 ℃)
    TT03Clamp-on, IP68. Operating temperature:-40 ℉ ~ +266℉(-40℃ ~ +130 ℃)
    TT05Insertion, IP68. Operating temperature:-40 ℉ ~ +266 ℉(-40℃ ~ +130 ℃)
    CodeTransducer Cable Length
    030Standard length 30ft (9m)
    XXXMax length to 1000ft (300m)
    CodeTemperature Transducer
    PT1000PT1000 temperature transducer+RTD module(option)
    CodeData Logger
    SDSD card(8G)+ SD card module(option)

    Standard model: ML-6100S-1-TT01-030

    Description: Standard clamp-on type ultrasonic flow meter, OCT, Relay,

    RS485, 4-20mA, 30ft cable with TT01 transducers


    V. Installation Site Selection

    The first condition for ultrasonic flow meter is the pipe must be full of liquid, the bubbles will greatly influence the accuracy of the measurement, please avoid the follow installation position.


    The suggestion installation area is as following:

    A is for upright pipeline, please notice the water direction is from the bottom to top.

    B is for horizontal pipeline, the transducers need to be installed inside the C area,angle for area C, max 120°