Sign In | Join Free | My himfr.com
Home > Electromagnetic Flow Meter >

China Remote Electromagnetic Flow Meter With Indicator And Totalizer

    Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
     
    Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
    • Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
    • Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
    • Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
    • Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
    • Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers
    • Buy cheap China Remote Electromagnetic Flow Meter With Indicator And Totalizer from wholesalers

    China Remote Electromagnetic Flow Meter With Indicator And Totalizer

    Ask Lasest Price
    Model Number : MLF
    Price : Negotiation
    Payment Terms : T/T
    Supply Ability : 500pcs per month
    Delivery Time : 7-10 working days
    • Product Details
    • Company Profile

    China Remote Electromagnetic Flow Meter With Indicator And Totalizer

    China Remote Electromagnetic Flow Meter With Indicator And Totalizer


    1. Introduction

    The MLF electromagnetic flowmeter works according to Faraday's law of electromagnetic induction and consists of a sensor and a converter. Used to measure the conductivity of liquids or solids. Under normal circumstances, its conductivity should be greater than 5μS/cm (the conductivity of tap water and raw water is about 100-500μS/cm), and it can also be used to measure acids, alkali, brine, pulp or pulp and other media. But these media cannot contain a lot of magnetic substances and bubbles.

    MLF electromagnetic flowmeter is an instrument for measuring liquid fluidity. It is widely used in flow measurement in metallurgy, chemical industry, paper making, environmental protection, petroleum, textile, food, urban management, water plant and other industries.

    Administration, Water Works,etc.


    2. Quick Details

    MLF electromagnetic flowmeter is explosion-proof design.

    Function of low conductivity measurement.

    There are nine languages(Chinese, English, Korean, Polish, Turkish, French and Portuguese languages) options to meet the needs of different customers.

    It has the function of self-regulation and self-examination.

    Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.


    3. Specification

    MLF TypeDivided TypeIntegrated TypeExplosive Proof Integrated TypeBattery Powered TypeHeat Energy Type
    Accuracy±0.2% or ±0.5%
    Pipeline DiameterDN10-DN2000DN10-DN600DN25-DN2000
    FlangeGB, ANSI, JIS, BS, Others
    PressureDN10-DN600 1.0 1.6 2.5 4.0MPa
    DN700-DN2000 0.6 1.0 1.6MPa
    Liner MaterialCR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
    Conductivity≥5µs/cm(Please contact us if it is less than 5µs/cm)
    Electrode316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
    Protection ClassIP65, IP66, IP67, IP68
    Medium Temperature-25~180
    (Please refer to liner material)
    -25~80(Please refer to liner material)-25~180
    (Please refer to liner material)
    Ambient Temperature for Accuracy Influence<±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
    Repetability≤±0.1% or ±0.25%
    Analog Output Error≤±0.02mA
    Velocity0.3~10m/s
    Electrical connectionM20x1.5 Seal Cartridge, GB1/2, NPT1/2
    Output4-20mA, Pulse, RS485, Hart, Profibus

    4. Selection of Liner Material

    Liner MaterialMain PerformanceApplication
    PTFE

    1 It has the most stable chemical properties in plastics, resistant to boiling hydrogen chloride and sulfuric acid, nitric acid, aqua regia, strong alkali and various organic solvents, but not resistant to chlorine trifluoride, high temperature nitrogen trifluoride, liquid fluorine, and liquid oxygen And ozone corrosion.

    2 Low wear resistance.

    3 Low negative pressure resistance.

    1. -25~140℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare medium

    CROil proof, solvent resistance, oxidatite resistance and the resistance to the erosion of common medium like acid, alkali, salt, etc.

    1. <80℃

    2. Be able to measure sewage and mud

    PU

    1. Very good abrasive resistance, flexibility.

    2. Low acid and alkali resistance.

    1. <65℃

    2. Neutral strong abrasion resistance medium

    Hard Rubber

    1 Room temperature resistance, hydrochloric acid, acetic acid, oxalic acid, ammonia, phosphoric acid and 50% sulfuric acid, sodium hydroxide, potassium hydroxide

    2 Avoid strong oxidants

    1. <80℃

    2. General acid, alkali, salt solution

    PFA

    1. Can be used for most corrosive medium like acides, alkalis, and strong oxidant.

    2. High material strength, resistance to aging, better than PTFE, EFP in high temperature

    3. Injection molding for higher negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium

    FEP(F46)

    1. Hydrophobicity and non-viscous

    2. Corrosion resistance is inferior to PFA

    3. Negative pressure

    1. 40~180℃

    2. Strong corrosion medium, like strong acid and alkali

    3. Healthcare mdium


    5. Selection of Electrode Materials

    Electrode MaterialMain Performance
    316L

    Good nitric acid corrosion resistance, <5% sulfuric acid, acetic acid, alkaline liquid, sulfite under certain pressure, sea water, acetic acid, etc. corrosion at room temperature, can be widely used in petrochemical urea, vinylon, etc.

    Hb

    Good resistance to all hydrochloric acid with a concentration lower than the boiling point, and also resistant to corrosion by non-oxidizing acids, alkalis, sulfuric acid, phosphoric acid, hydrofluoric acid, and organic acids.

    Hc

    Corrosion resistance to oxidizing acids, such as nitric acid, mixed acids. A mixture of chromic acid and sulfuric acid, oxidizing salts such as Fe3+, Q3+, and some other oxidizing agents, such as a mixture of hypochlorite solution and seawater at higher than normal temperature.

    TiResistance the corrosion of seawater, various chlorides, hypochlorite, oxidizing acid(including fuming nitric acid), and organic acid or alkali, but don't be resistance to the corrosion of pure reducint acid(like sulfuric acid, hydrochloric acid). But if acid includes oxidants(like nitric acid, Fe3+, Q3+), the corrosion resistance will decrease.
    TaGood corrosion resistance similar to glass. Resistance to the corrosion of chemical medium(including hydrochloric acid and fumiing sulfuric acid), but can not be used for sodium hydromide fluid.
    Pt-IrHave good corrosion resistance of all acid, and can be resistance to the corrosion of alkali, all salt except aqua regia, ammonium slat and few other medium
    Tungsten CarbideFor pulp and sewage, good resistance to solid particle interference.

    6. Dimensional Sketches

    a. Dimension of Converter

    China Remote Electromagnetic Flow Meter With Indicator And Totalizer

    Divided Type


    China Remote Electromagnetic Flow Meter With Indicator And Totalizer


    Integrated Type


    China Remote Electromagnetic Flow Meter With Indicator And Totalizer

    Battery Powered Type


    b. Dimension of Sensor



    Pipeline DiameterDimension
    LWH
    1516095130
    20160105137
    25160115150
    32160135160
    40200145175
    50200160185
    65200180205
    80200195215
    100250215235
    125250245275
    150300280300
    200350335355
    250400400405
    300500455460
    350500515520
    400600575580
    450600635630
    500600710685
    600600835795
    700700905910
    80080010201030
    90090011201120
    1000100012451250
    1200120014651470

    7. Advantages & Disadvantages

    There are numerous benefits to using electromagnetic flowmeters to perform fluid flow measurements. They are generally non-invasive and have no moving parts, reducing the risk of breakdowns and the frequency of repairs. A decrease in flowmeter pressure is also usually no greater than that of an equivalent pipe length, reducing the piping costs. Some of the other major advantages provided by magnetic flowmeters include:

    • Power usage is relatively low, with electrical power requirements as low as 15 watts for some models.
    • They are mechanically obstructionless and can be equipped with abrasion-resistant liners, making them effective for measuring slurries and other erosive fluids.
    • They are capable of dealing with most kinds of acids and bases, as well as water and water-based solutions, due to lining materials that are both insulators and have corrosion resistance.
    • Relatively small amounts of electrode metals are needed for magnetic flowmeters.
    • They can measure both very low flows and very high volume flow rates, with a minimum diameter of roughly 0.125 inches and a maximum volume of up to 10 cubic feet.
    • They can usually measure multidirectional flow, either upstream or downstream.

    Despite these advantages, magnetic flowmeters also present certain difficulties for flow rate measurement. These flowmeters are only effective on conductive fluids, and materials such as unmixed hydrocarbons and gases cannot be measured. However, magnetic materials themselves may also present problems, as hydrodynamic effects can alter the normal flow pattern and disturb the velocity rate enough to interfere with operations. Depending on their size and capacity, magnetic flowmeters can be relatively heavy, and those with higher corrosion and abrasion resistance can be expensive.


    Quality China Remote Electromagnetic Flow Meter With Indicator And Totalizer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)